Mining intrinsic safety explosion-proof magnetic proximity switch CJK-2C with CJK-2Z

The intrinsically safe explosion-proof magnetic proximity switch CJK-2C and CJK-2Z for mining are used to detect the permanent magnet fixed on the tested object and sense the proximity of the position. When the tested permanent magnet or object approaches the required opening distance (adjustable), the output switch signal or indicator light will light up. Due to the use of non-contact detection, it has speed, longevity, and reliability; The characteristic of stable operation in humid and corrosive environments or in flammable (explosive) environments

  • ZHUOXIN
  • 24v-110v-220v-380v
  • IP65
  • TT, Paypal, Credit card, Western union
  • +86-15163766288
  • The intrinsically safe explosion-proof magnetic proximity switch CJK-2C and CJK-2Z for mining are used to detect the permanent magnet fixed on the tested object and sense the proximity of the position. When the tested permanent magnet or object approaches the required opening distance (adjustable), the output switch signal or indicator light will light up. Due to the use of non-contact detection, it has speed, longevity, and reliability; The characteristic of stable operation in humid and corrosive environments or in flammable (explosive) environments

Description

Conveyor switch

The intrinsically safe explosion-proof magnetic proximity switch CJK-2C and CJK-2Z for mining are used to detect the permanent magnet fixed on the tested object and sense the proximity of the position. When the tested permanent magnet or object approaches the required opening distance (adjustable), the output switch signal or indicator light will light up. Due to the use of non-contact detection, it has speed, longevity, and reliability; The characteristic of stable operation in humid and corrosive environments or in flammable (explosive) environments& HANGRONG/Zhuoxin stock, product description: The magnetic proximity switch is composed of two parts: a magnet and a switch contact. Magnets are divided into two types: electromagnets and permanent magnets, and can be selected according to the needs of control. The switch contacts are divided into three forms: normally open contact, normally closed contact, and transfer control contact, which are also selected according to actual needs. The magnet and contact should be installed on the same axis, and the distance between the two should be within the working distance. There should be no strong magnetic field around the switch contacts to avoid any impact. Electromagnets require direct current 24V power supply, and the two leads of the switch contacts should be connected in series to the power supply and load, and should not only be connected to the power supply, causing short circuiting and burning of the contacts. The wiring should be as short as possible and as far away from the wiring as possible. 2. Functional non memory magnetic proximity switches should be non-contact and have on/off or switching functions to achieve alignment, limiting, and various control purposes. CKJ series function introduction: Configure the number of contacts and magnets for magnetic proximity switches based on the on-site detection and control points of each user. Magnetic proximity switch CJK-2C+CJK-2Z proximity switch LJ18A3-8-J/EZ, normally open, 8mm, 90-250VAC proximity switch Ni15-M30-BP6L proximity switch NBB10-30GM50-E2 proximity switch NBN15-30GM50-E2 temperature resistant proximity switch ES 516-549-S4-H-T120 12-32VC Sn15 normally open temperature resistant 120 ° magnetic switch CK-A magnetic switch CS1-F  Proximity switch JL18A3-8-Z/BX Proximity switch LJ18A3-5-Z/BX Proximity switch LJA18M-10A1 Proximity switch LJA12M-51 Installation requirements: can be installed indoors and outdoors, suitable for ambient temperature of -55 ℃~125 ℃ Contact mining intrinsic safety explosion-proof magnetic proximity switch CJK-2C plus CJK-2ZCJK series Technical performance indicators: 1. Large action distance: 120mm 2. On off difference: within 30mm 3. Response time: less than 10ms 4. Vibration frequency: 20G 10-1000HZ 5. Excitation voltage: C24V& Plun; 2V6. Excitation current: 0.6A7. Environmental humidity: -55 ℃& Mash;+125 ℃ 8. Contact large capacity: 80VA 9. Large switching current: 0.8A10. Large switching voltage: C350V AC300V11. Contact resistance: less than 0.1Ω 12. Weight: 3.6kg magnet, 0.6kg contact. 13. Using JZ7-44 as the load, the lifespan is 500000 times;  & nbsp;

Tags

Get the latest price? We'll respond as soon as possible(within 12 hours)
主站蜘蛛池模板: 欧美激情一区二区三级高清视频 | 狠狠草视频 | 亚洲一区免费 | 国产成人精品在线观看 | 亚洲午夜大片 | 伊人国产精品 | 成人欧美日韩一区二区三区 | 婷婷人人爽人人做人人添 | 国产精品久久久久久久久久 | 成年网站在线观看 | 日韩亚洲欧美视频 | 欧美精品一区二区三区在线播放 | 一区二区国产在线播放 | 亚洲草原天堂 | 日韩欧美精品综合一区二区三区 | 日本黄色性视频 | 性夜黄a爽影免费看 | 欧美顶级毛片在线播放 | 538prom国产在线视频一区 | 91精品国产综合久久精品 | 国产女主播喷出白浆视频 | 国产成人久久精品二区三区牛 | 99re6热只有精品免费观看 | 免费啪视频在线观看免费的 | 精品一区二区三区在线视频 | 婷婷开心六月久久综合丁香 | 亚洲网站一区 | 日韩电影网站 | 日本理论片好看理论片 | 欧美日韩大尺码免费专区 | 日本女人毛茸茸 | 日韩视频第二页 | av在线播放国产 | 91华人在线视频 | 亚洲精品一区二区三区在线观看 | 国产高清在线视频 | 91精品国产一区二区 | 欧美一区二区 | 欧美一级成人免费大片 | 成人毛片视频免费看 | 亚洲欧美日韩精品久久奇米色影视 |