TCK-2P Mining Magnetic Switch TCK/KGE

TCK/KGE mining magnetic switch, Zhuoxin Electric, corresponding accessories for mining lifting. Our company's TCK and KGE series magnetic switches are mainly used in mine shafts as cage positioning signals and lifting degree indicators. Widely used, it can detect objects at distances of 250mm, 360mm, and 500mm when used in conjunction with corresponding magnets.

  • TCK-2P
  • ZHUOXIN
  • 24v-110v-220v-380v
  • IP65
  • TT, Paypal, Credit card, Western union
  • +86-15163766288
  • TCK/KGE mining magnetic switch, Zhuoxin Electric, corresponding accessories for mining lifting. Our company's TCK and KGE series magnetic switches are mainly used in mine shafts as cage positioning signals and lifting degree indicators. Widely used, it can detect objects at distances of 250mm, 360mm, and 500mm when used in conjunction with corresponding magnets.

Description

Conveyor switch

Shandong Zhuoxin Electric TCK series magnetic switch< Simultaneously TCK-2, TCK-3, and TCK-4 magnetic switches< Magnetic switch performance parameters:
1. Power supply voltage: AC; 85-265v< br />2、 Contact parameters: 127v& nbsp;  2A 。
3、 Number of contacts: Two sets of normally open and normally closed points< br />4、 Speed response: can meet the speed requirement of 30M/S< br />5、 Working frequency: The mechanical life of the contacts can reach 90000 times< Our company's mines upgrade corresponding accessories. Our company's TCK and KGE series magnetic switches are mainly used in mine shafts as cage positioning signals and lifting degree indicators. Widely used, it can detect objects at distances of 250mm, 360mm, and 500mm when used in conjunction with corresponding magnets. TCK/KGE mining magnetic switch, Zhuoxin Electric, corresponding accessories for mining lifting. Our company's TCK and KGE series magnetic switches are mainly used in mine shafts as cage positioning signals and lifting degree indicators. Widely used, it can detect objects at distances of 250mm, 360mm, and 500mm when used in conjunction with corresponding magnets. Our company is a TCK series magnetic switch manufacturer with sensitivity, accuracy, and polarity of unipolar magnetic sensors. We also have independent intellectual property rights in this technology< Based on sensitivity unipolar magnetic switches, the company has developed TCK series magnetic switches and TK mining sealed magnetic induction switches for use in mining industry shafts< The company's portable steel core belt joint detector weighs only 2KG. The steel core belt detector can accurately determine the position and tension of the steel core belt joint, overcoming the problem of mining belt users being unable to detect the tension of the steel core belt joint; Ensuring the use of steel core belts, the company has applied for intellectual property protection for this technology and owns * independent intellectual property rights< The company is committed to providing customers with high-quality products with a spirit of harmony and demand. The types and identification methods of TCK series magnetic switches: 1. There are two types of TCK series magnetic switches: 1. Unipolarity: magnetic switches have an effect on the S pole of the magnet, but no effect on the N pole. This type of magnetic switch has strong capabilities; At the same time, unipolar magnetic switches can affect the magnetic switch after cage magnetization, which cannot be achieved by bipolar magnetic switches. This type of magnetic switch is more effective< The second type is bipolar: magnetic switches have an effect on both the S and N poles of the magnet. However, for the case where the cage is magnetized, bipolar magnetic switches cannot be used well, often causing inaccurate alignment, signal errors, and making it difficult for users to use. This type of magnetic switch is relatively widely used on site due to its strong capability, while bipolar magnetic switches are less commonly used because they are easily affected by cage magnetization< There are many types of magnetic switches available on the market now, including KGE1, TCK, TK, etc. There are also a few, but there are very few qualified magnetic switches on the market now< Secondly, there are five indicators for judging the performance of magnetic switches:
1. Appearance of the product: the appearance should be designed to be beautiful, clean, and the surface of the sealed colloid should be flat and shiny< br />2、 Using connecting cables: Check whether the wires inside the cables are copper or tin plated. Tin plated wires have much better performance than copper wires and are also more expensive (10 core cables). Generally, cheap copper core wires are used to save costs< br />3、 Reaction of magnetic switch to magnet: When the magnetic switch is used in combination with TS250 magnet, the large distance between the magnet and the magnetic switch is 245mm~255mm. Products larger than 260mm and smaller than 240mm are not qualified< br />4、 The influence of geomagnetism on magnetic switches: A good magnetic switch needs to have good capabilities, and one of the main indicators for judgment is the influence of geomagnetism on magnetic switches. The testing method is as follows: using the TS250 magnet as an example, point the head of the magnetic switch towards the geographical south and geographical north respectively, and then align the S-pole row of the TS250 magnet with the head of the magnetic switch for testing; In both cases, the large distance between the magnetic switch and the TS250 magnet should be within the range of (245mm, 255mm), with an interval of 10mm. The shorter the interval, the smaller the influence of geomagnetism, and in good cases, the interval is around 5mm. If the interval is greater than 15mm under the influence of geomagnetism, it is not a qualified and good product< br />5、 When using a magnet to approach the magnetic switch from far to near, the distance between the magnet and the magnetic switch is represented by L when L> At 255mm, the magnetic switch does not operate, and at 100mm< L<255mm, The magnetic switch is in the active state when L< 100mm magnetic switch in non operating state; This can control the installation position on site and improve the positioning of the magnetic switch. So when installing the magnetic switch, the distance between the magnet and the magnetic switch should be (120mm, 220mm) TCK/KGE mining magnetic switch, mining switch, induction switch SC3015-PM1 SC3015-P2K1、SC3015-P2M1SCS3010-N、SCS3010-N2、SCS3010-P、SCS3010-P2、SCS3010-NK、SCS3010-N2K、

Tags

Get the latest price? We'll respond as soon as possible(within 12 hours)
主站蜘蛛池模板: 99热综合 | 欧美一级片| se就是色94欧美setu | 播放毛片| 台湾一级毛片永久免费 | 欧美簧片在线 | 香蕉在线影院 | 国产精品美女久久久 | 一区二区三区欧美大片 | 成熟人妻AV无码专区A片 | 日韩在线视频在线 | 欧美午夜视频 | 无码免费一区二区三区免费播放 | 亚洲www啪成人一区二区 | 日韩在线观看第一页 | 亚洲精品午夜电影 | 亚洲国产七七久久桃花 | 国产亚洲精品不卡在线 | 日韩成人在线视频 | 国产午夜精品一区二区三区嫩草 | 欧美成人黑人视频免费观看 | 6080yy精品一区二区三区 | 日韩男女做性高清在线观看 | 亚洲国产午夜 | gogo全球大胆高清人露出91 | 亚洲免费视频网站 | 久草视频官网 | 亚洲v日本v欧美v综合v | 免费久久网站 | 三级全黄a | 色偷偷噜噜噜亚洲男人 | 亚州男人天堂 | 亚洲娇小性色xxxx | writeas桌下口 | 97在线视频免费 | 亚洲一区二区三 | 久久成人一区二区 | 欧美亚洲综合久久 | 久久99精品久久 | 日本jizzz | 奇米777视频 |